4 Way Hydrant Valve
About The Item
This valve allows you to provide water to the fire at
hydrant pressure, while waiting for a second pumper
to hook up and increase flow and pressure.,br>
• Flow efficient 3 1⁄2" waterway
• 75 psi maximum pressure differential during changeover
• 300 psi maximum operating pressure
• 1000 gpm maximum flow when changing the ball position
How It Works:
Step 1 - Attach the 4-Way Hydrant Valve to the hydrant and
forward lay to the engine at fire scene.
Step 2 – Attach a hose from the 4-Way Hydrant Valve to the
intake on the engine at the hydrant.
Step 3 – Attach a hose from the discharge on the engine at
hydrant to the 4-Way Hydrant Valve inlet.
Establish recirculating flow at hydrant pressure.
Step 4 – Rotate the handwheel on top of the 4 way Hydrant
Valve to introduce pressurized flow from the engine
at the hydrant to the engine at the fire scene. Increase
pressure on the pumper to increase flow as required.